Việt Nam
English
Marechal
  • Công-ty-CP-Kỹ-Thuật-TM-Thiết-Bị-Công-Nghiệp-NTD-359601070816160/
    TRANG CHỦ
    GIỚI THIỆU
    SẢN PHẨM
    BẢN TIN CÔNG TY
    TUYỂN DỤNG
    LIÊN HỆ
Pressure Gauges Thermocouples Pressure Switch Pressure Sensor Compensating Cable/Duplex Wire Digital Pressure Gauge Resistance Temperature Detectors Temperature Pressure Thermowells Flow & Heat metter
Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Tower Light Limit Alarms Gateway-Remote-I/O Paperless Recording System PC Recorder Web Data Loggers PID Control Components Temperature Controllers Electric Actuators Lightning Surge Protectors
Asco Manually Operated Valves ASCO Medical and Analytical Valves ASCO Numatics Valve Islands ASCO Oil & Gas Valves (ATEX) ASCO Pneumatic Accessories ASCO Proportional Technology Aventics Compressed Air Preparation Aventics Cylinder Accessories Aventics Electrical Connection Technologies Aventics Flow and Check Valves Aventics Pneumatic Connection Technologies Aventics Pressure Regulators Aventics Sensors Aventics Vacuum Technologies Aventics Valves and Valve Systems
Burner Controls Flame Amplifiers For Microprecessor Control Flame Amplifiers For Electromechanical Control ULTRAVIOLET MODUTROL MOTOR SENSORS HONEYWELL MICRO SWITCH SNAP-ACTION SERIES MICRO SWITCH HAZARDOUS AREA SWITCHES KEY AND ROTARY SWITCHES MICRO SWITCH LIMIT SWITCHES Pressuretrol MICROPROCESSOR DISPLAY MODULE MICROPROCESSOR RELAY MODULE ELECTROMECHANICAL RELAY MODULE RELAYS HONEYWELL
Bộ điều khiển nhiệt độ SDC Azbil Burner Controller Azbil Recorder Flame Detector Pressure Transmitters
DECONTACTOR™=SWITCH+SOCKET-OUTLET RETTBOX® (Rescue) MULTICONTACT CONNECTORS INDUSTRIAL PLUGS & SOCKET-OUTLETS SINGLE POLE POWER CONNECTORS CUSTOM SOLUTIONS MULTICONTACT EX EX INDUSTRIAL PLUGS SINGLE POLE EX EX CUSTOM SOLUTIONS
Accessories Actuators - Bộ truyền động Data acquisition and recording Emissions and Combustion Analysis Industrial Automation Sensors and Transmitters Refrigeration
DANH MỤC SẢN PHẨM
  • NAGANOKEIKI NAGANOKEIKI
  • YAMARI - Temperature sensor YAMARI - Temperature sensor
  • M-SYSTEM M-SYSTEM
  • Signal Conditioners
    Two-wire Signal Conditioners
    Power Transducers
    Indicators
    Tower Light
    Limit Alarms
    Gateway-Remote-I/O
    Paperless Recording System
    PC Recorder
    Web Data Loggers
    PID Control Components
    Temperature Controllers
    Electric Actuators
    Lightning Surge Protectors
  • ASCO NUMATIC ASCO NUMATIC
  • BARKSDALE BARKSDALE
  • HONEYWELL HONEYWELL
  • AZBIL - YAMATAKE AZBIL - YAMATAKE
  • MARECHAL MARECHAL
  • ORANGE RESEARCH ORANGE RESEARCH
  • ASCON TECHNOLOGIC ASCON TECHNOLOGIC
  • MAXON - BURNER MAXON - BURNER
  • ECLIPSE - BURNER ECLIPSE - BURNER
  • KROMSCHRODER KROMSCHRODER
  • HUBA CONTROL HUBA CONTROL
  • OMRON OMRON
  • FANTINELLI FANTINELLI
  • HANYOUNG NUX HANYOUNG NUX
  • SCHNEIDER SCHNEIDER
  • TECHNOR TECHNOR
  • STARRETT STARRETT
  • OXFORD-USA OXFORD-USA
  • GENERAL GENERAL
  • DURAG DURAG
  • TESCOM TESCOM
  • MATSUSHIMA MATSUSHIMA
  • DELTA MOBREY DELTA MOBREY
  • GASTRON GASTRON
  • DITEL DITEL
  • TOPWORX TOPWORX
  • ASHCROFT ASHCROFT
  • Taik Electric Taik Electric
  • OPTONE OPTONE
  • GF GF
  • Sirai Sirai
  • ĐỐI TÁC
    • Signal Conditioners
      Signal Conditioners
    • Temperature sensor
      Temperature sensor
    • Process Control - FSG
      Process Control - FSG
    • FLUID CONTROL
      FLUID CONTROL
    • Advance Automation
      Advance Automation
    • Industrial automation Refrigeration
      Industrial automation Refrigeration
    • HUBA CONTROL – For Fine Pressure And Flow Measurement
      HUBA CONTROL – For Fine Pressure And Flow Measurement
    • ELECTRICAL PLUGS & SOCKET-OUTLETS
      ELECTRICAL PLUGS & SOCKET-OUTLETS
    • BURNER
      BURNER
    • BURNER
      BURNER
    M-SYSTEM >> Web Data Loggers

    DL8 WEB-ENABLED REMOTE TERMINAL UNIT

    Cập nhật: 2/17/2020 - Số lượt đọc: 2234
    Thông tin sản phẩm
    Giá: Call  
    Hãng sản xuất: M-system  
    Bảo hành: Số lượt xem:2234  
    DL8 Web Data Logger DL8

    WEB-ENABLED REMOTE TERMINAL UNIT

    Functions and features
    • Remote monitoring of equipment and plants by using modern communication infrastructure
    • Monitoring and logging of a wide variety of signals including temperature, pressure, voltage, discrete signal status
    • Flexible I/O types and scalable points by combining built-in R8 Series I/O modules
    • Type A has basic 'Browsing' function with web browser.
    • Type B is added with 'Reporting' function by e-mails.
    • Type C is added with 'Recording' function with SD card.
    • Type D is added with 'Advanced' functions of peer-to-peer connection of I/O signals and customized web browser view.

    MODEL: DL8–[1]–R[2]

    ORDERING INFORMATION
    • Code number: DL8–[1]-R[2]
    Specify a code from below for each [1] and [2].
       (e.g. DL8-D-R/Q)
    • Specify the specification for option code /Q
       (e.g. /C01)

    [1] MODULE TYPE
    A: Modbus/TCP (Ethernet) (Server/client)
    Web server
    B: Modbus/TCP (Ethernet) (Server/client)
    Web server, reporting by e-mail, FTP client
    C: Modbus/TCP (Ethernet) (Server/client)
    Web server, reporting by e-mail, FTP server/client, data logger
    D: Modbus/TCP (Ethernet) (Server/client)
    Web server, reporting by e-mail, FTP server/client, data logger,
    I/O mapping, user-defined Web browser view

    POWER INPUT
    DC power
    R: 24 V DC
    (Operational voltage range: ±10 %; ripple 10 %p-p max.)

    [2] OPTIONS
    blank: none
    /Q: With options (specify the specification)

    SPECIFICATIONS OF OPTION: Q
    COATING (For the detail, refer to M-System's web site.)
    /C01: Silicone coating
    /C02: Polyurethane coating

    RELATED PRODUCTS
    R8 Series remote I/O modules
    (model: R8-SS2, R8-SS4NJ, R8-SS4N, R8-SST8, R8-SV2, 
    R8-SV4N, R8-FS16N, R8-TS2, R8-RS4N, R8-CT4E, R8-YS2, 
    R8-YS2NJ, R8-YST4N, R8-YV4N, R8-PA4, R8-PA4F, R8-PC4A, 
    R8-DA4A, R8-DAM16A, R8-DAT16A2, R8-DC4A, R8-DC4A2, 
    R8-DC4C, R8-DCT4D, R8-DCM16A, R8-DCM16ALZ, 
    R8-DCM16ALK, R8-DCM16ALH, R8-DCM32B2, R8-DCT16A2, 
    R8-PS1)
    • PC Configurator cable (model: MCN-CON or COP-US)
    • PC configurator software (model: DLCFG)
    • PC configurator software (model: R8CFG)
    Software downloadable at M-System’s web site.
    • SD card
    An SD card is necessary to store data.
    Use the specified model number of memory card.
    Available for purchase from M-System. Consult M-System.
      - Hagiwara Solutions NSD6-004GH 
      (NSDA-004GL ... discontinued)

    PACKAGE INCLUDES...
    • Protective cover
    • Ferrite core

    GENERAL SPECIFICATIONS
    Connection
    •Power supply (exc. supply), RUN contact output:
     Tension clamp terminal (Front Twin connection)
     Unit side connector: MSTB2,5/5-GF-5,08AU
     Cable side connector: TFKC2,5/5-STF-5,08AU
     (Applicable wire size: 0.2 - 2.5 mm2, stripped length 10 mm)
      Recommended solderless terminal
      AI0,25-10YE 0.25 mm2 (Phoenix Contact)
      AI0,34-10TQ 0.34 mm2 (Phoenix Contact)
      AI0,5-10WH 0.5 mm2 (Phoenix Contact)
      AI0,75-10GY 0.75 mm2 (Phoenix Contact)
      AI1-10RD 1.0 mm2 (Phoenix Contact)
      AI1,5-10BK 1.5 mm2 (Phoenix Contact)
      AI2,5-10BU 2.5 mm2 (Phoenix Contact)
    •Ethernet: RJ-45 connector
    •Internal bus, internal power, exc. supply: Connector
    Housing material: Flame-resistant resin (gray)
    Max. number of I/O modules: 16
    (Max. consumption current of I/O modules: 1.6 A)
    Isolation: Ethernet to internal bus or internal power or power supply (exc. supply) to RUN contact output to FE
    (No isolation between discrete input/output and power supply of the I/O modules when used with the DL8.)
    Calendar clock: Year (4 digits), month, date, day, hour, minute, second
    Status indicator LED: POWER, LOGGING, SD CARD, SEND, COM, ERROR
    RUN contact output: Photo MOSFET relay (no polarity);
    (OFF in error detected)
    •Peak load voltage: 50 V max.
    •Continuous load current: 50 mA max.
    •Peak load current: 300 mA max. (≤0.1 sec.) 
    •Operation
      Power down: OFF
      Firmware operating: ON
      Error in Ethernet LNK: OFF
      Internal bus error: OFF
      SD card writing error: OFF
     (Run contact output is applicable for Type C with the DL8 firmware version 1.4.x or later.)

    ETHERNET COMMUNICATION
    Communication Standard: IEEE 802.3u
    Transmission: 10BASE-T, 100BASE-TX
    Baud rate: 10/100 Mbps (Auto Negotiation function)
    Protocol: TCP/IP, Modbus/TCP, HTTP, FTP, SMTP, SNTP
    Transmission media: 10BASE-T (STP, Category 5), 100BASE-TX (STP, Category 5e)
    Max. length of fieldbus segment: 100 meters
    Ethernet indicator LED: DPLX, LNK
    IP address: 192.168.0.1 (factory setting)

    INSTALLATION
    Power consumption
    •DC: Approx. 12 W 24 V DC (@ internal power max. current 1.6 A) )
    Internal power supply (power supply for I/O module):
    • DC power supply: 5 V DC
    • Current capacity: 1.6 A
    Excitation supply output (excitation for I/O module)
    •DC: 24 V DC ±10 %
    •Operational current: 7 A
     (From power supply (exitation supply) connector, via connector for internal bus, supplied to each I/O module. Power output current consumption must be under operational current.)
    Operating temperature: -10 to +55°C (14 to 131°F)
    Operating humidity: 30 to 90 %RH (non-condensing)
    Atmosphere: No corrosive gas or heavy dust
    Mounting: DIN rail
    Weight: 190 g (0.42 lb)

    PERFORMANCE
    Battery: Vanadium-lithium secondary battery (undetachable)
    Calendar clock accuracy: Monthly deviation 2 minutes at 25°C
    Battery backup: Approx. 2 months
    Insulation resistance: ≥ 100 MΩ with 500 V DC
    Dielectric strength: 1500 V AC @ 1 minute (Ethernet to internal bus or internal power or power supply (exc. supply) to RUN contact output to FE)

    STANDARDS & APPROVALS
    EU conformity:
    EMC Directive 
      EMI EN 61000-6-4
      EMS EN 61000-6-2
    RoHS Directive
      EN 50581

    COMPATIBLE BROWSING DEVICE
    ■ Software requirement
    Functional checked environment
    PC
    •OS:
     Windows 7 (32-bit/64-bit), Windows 8.1 (32-bit/64-bit)), Windows 10 (32-bit/64-bit)
    •Browser:
     Internet Explorer 11
     Microsoft Edge
     Firefox 61.0.1
     Chrome 68.0.3440.75
    Tablet
    •OS:
     iPad (iOS 11.4.1); Android terminal (Android 8.0)
    •Browser:
     iOS: Safari; Android: Chrome
    Smart phone
    •OS
     iPhone (iOS 11.4.3); Android terminal (Android 8.0)
    •Browser:
     iOS:Safari; Android: Chrome

    BASIC CONFIGURATIONS
    The modules' addresses can be set freely from 0 to 31 regardless the mounting location. However, be sure not to use duplicated addresses.  A 4-point analog I/O module occupies 2 addresses.  E.g. when R8-SV4N is set to address 5, Input 1 and Input 2 are assigned to address 5, Input 3 and Input 4 are assigned to address 6.  In this case, do not set other I/O modules to address 6.

    EXTERNAL VIEW

    CONNECTION DIAGRAMS

    EXTERNAL DIMENSIONS unit: mm (inch)

    SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
    Note: In order to improve EMC performance, bond the FE terminal to ground.
    Caution: FE terminal is NOT a protective conductor terminal.

    COMMUNICATION
    IP:
    DHCP client is supported. Manual setting of IP address, subnet mask, default gateway and DNS server available too.
    Modbus/TCP slave:
    Remote observation system via SCADA etc.
    Modbus/TCP master:
    I/O expansion with remote I/O, e.g. R3 or R7 series, is available. Measuring points in multiple locations can be handled collectively.
    Web server function (Direct):
    This unit can be a Web server, and 'Data,' 'Trend' and 'Event Log' views are available from remote location.
    Web server function (Cloud):
    This unit can be an FTP client, and upload the Web files to a cloud server.
    Users can browse the cloud server.
    Multiple users can access it at once without extra load at the unit. (only browsing, operation not available.)
    Analog input: 32 points
    Discrete input: 64 points
    Pulse input: 32 points
    Diescrete output: 64 points 
    Analog output: 32 points (firmware version of the unit: 1.4.x or later)
    * For pulse input, only 32 bit data is available. It is not available for the products using 16 bit data (model: R3-PA16 etc.).

    ALARM OUTPUT (Type B, C & D)
    Event can trigger an alarm contact at a discrete output module.
    •Transition of analog input zone
    •Transition of pulse input zone
    •Status change of discrete input
    •Count up of discrete input

    EVENT REPORTING E-MAIL (Type B, C & D)
    Reporting e-mail function available at event or designated time.
    Encrypted communication is supported. (SMTP over SSL).
    The DL8 turns a designated Do ON after transmitting the report.
    · Number of e-mail attention: 32
    · Number of event report text: 32
    · Number of regular report text: 1
    · Channel status: AI, DI, PI, DO, AO status attachable to e-mail
    (DO and AO are available with firmware version of the unit 1.4.x or later) 
    · Output at transmitting failure: 1 point

    LOGGING (Type C & D)
    Log files in text format are stored into an SD card. The number of logs depends on the free space of the SD card.  
    Log file: System log, event log, e-mail report log, channel log

    FTP CLIENT (Type B, C & D)
    The recorded data is uploaded to an FTP server in CSV format in specified interval time.
    User can define the CSV file.
    •Number of channel: Max. 32 (Selectable within AI, DI, DI (counter), PI, DO, AO)
    (AO is selectable with firmware version of the unit 1.4.x or later)
    •Sampling rate (Firmware version 1.6.x or later)
     1 or 2 sec (Interval time: 1 or 10 min. or 1 hr.)
     5, 10 or 30 sec. (Interval time: 10 min. or 1 hr.)
     1, 2, 5, 10, 15, 20 or 30 min. (Interval time: 1 day)
    •Sampling rate (Firmware version 1.2.x or later)
     1 or 2 sec (Interval time: 1 or 10 min. or 1 hr.)
     5, 10 or 30 sec. (Interval time: 10 min. or 1 hr.)
     1, 2, 5, 10 or 30 min. (Interval time: 1 day)
    •Sampling rate (Firmware version 1.1.x or earlier)
     1, 2, 5, 10 or 30 sec. (Interval time: 1 hr.)
     1, 2, 5, 10 or 30 min. (Interval time: 1 day)
    Note: To confirm the firmware version, use the configurator software, model: DLCFG.

    TREND DATA STORING (Type C & D)
    The logged data is written into the SD card in CSV format.
    User can define the CSV file.
    •Number of channels: Max. 32 (Selectable within AI, DI, DI (counter), PI, DO, AO)
    (DO and AO are selectable with firmware version of the unit 1.4.x or later)
    •AI sampling: Momentary, average, peak (max.), peak (min.)
    •Logging rate:
     Second: 1, 2, 5, 10, 20, 30 sec.
     Minute: 1, 2, 5, 10, 15, 20, 30 min.
     (15 min. is selectable with firmware version 1.5.x or later)
     On the hour: 0 to 23 o’clock (1 or more times available; specify time delay for each set time)
     Day start time and days to log are available.
    •Recordable up to the SD card size.
     Automatically deleted.
     (Auto delete is available with firmware version of the unit 1.4.x or later)
    •Recording period (as a guide)
     Approx. 180 days
     (logging rate: 1 sec, 32 channels, only trend storing)

    FTP SERVER (Type C & D)
    Reading and deleting files in the SD card by an FTP client is available.
    Compatible FTP client
    •Explorer
    •FFFTP
    •Web browser
     Internet Explorer version 11
     Firefox version 61.0.1
     Chrome version 68.0.3440.75

    I/O MAPPING (Type D)
    Multiplex Data Transmission for remote I/O and IP telemeter is available by registering DI-to-DO or AI-to-AO mapping information.

    USER DEFINED BROWSER VIEW (Type D)
    The browser view is user-definable.
    Development tools for HTML file are not available by M-System. Provide by customer.

    OTHER FUNCTIONS
    Configuration: Configurable with the dedicated software model: DLCFG
    Time zone: Selectable between –12:00 and +13:00
    (Time zone setting by minutes is not available for the DL8 Ver.1.3 or earlier versions.)

    SYSTEM CONFIGURATION EXAMPLES
    Devices other than the DL8 in below provided by the user.

    M-System Vietnam
    Email: sales@m-system.com.vn
    Tags
    DL8 WEB-ENABLED REMOTE TERMINAL UNIT M-system Vietnam
    CÁC TIN KHÁC
    • DL8 WEB-ENABLED REMOTE TERMINAL UNIT
      Mã số : DL8 WEB-ENABLED REMOTE TERMINAL UNIT M-system Vietnam
      DL8 WEB-ENABLED REMOTE TERMINAL UNIT M-system Vietnam
      Giá:  Call
       | DL8 	WEB-ENABLED REMOTE TERMINAL UNIT
    • GR8-Series-Communication-Adaptor
      Mã số : GR8 Series Communication Adaptor M-system Vietnam
      GR8 Series Communication Adaptor M-system Vietnam
      Giá:  Call
       | GR8-Series-Communication-Adaptor
    Quảng cáo
    THỐNG KÊ

    may cat giay

    Lượt truy cập: 333594
    may cat giay
    Đang online: 10
    ĐỐI TÁC

    CÔNG TY CỔ PHẦN KỸ THUẬT VÀ THƯƠNG MẠI THIẾT BỊ CÔNG NGHIỆP NTD

    Địa chỉ: Số 28, ngõ 36 Cổ Linh, tổ 7, P. Long Biên, Q. Long Biên, TP. Hà Nội

    Hotline: 0971961212

    sales@ntd-automation.com

    Tags: Yamari Vietnam, M-System Vietnam, Honeywell, Azbil, Yamatake, Ascon Tecnologic, Asco Numatic,
    Thiết kế web bởi haanhco.,ltd
    0971961212 Facebook: 359601070816160Zalo: 0971961212