Việt Nam
English
Marechal
  • Công-ty-CP-Kỹ-Thuật-TM-Thiết-Bị-Công-Nghiệp-NTD-359601070816160/
    TRANG CHỦ
    GIỚI THIỆU
    SẢN PHẨM
    BẢN TIN CÔNG TY
    TUYỂN DỤNG
    LIÊN HỆ
Pressure Gauges Thermocouples Pressure Switch Pressure Sensor Compensating Cable/Duplex Wire Digital Pressure Gauge Resistance Temperature Detectors Temperature Pressure Thermowells Flow & Heat metter
Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Tower Light Limit Alarms Gateway-Remote-I/O Paperless Recording System PC Recorder Web Data Loggers PID Control Components Temperature Controllers Electric Actuators Lightning Surge Protectors
Asco Manually Operated Valves ASCO Medical and Analytical Valves ASCO Numatics Valve Islands ASCO Oil & Gas Valves (ATEX) ASCO Pneumatic Accessories ASCO Proportional Technology Aventics Compressed Air Preparation Aventics Cylinder Accessories Aventics Electrical Connection Technologies Aventics Flow and Check Valves Aventics Pneumatic Connection Technologies Aventics Pressure Regulators Aventics Sensors Aventics Vacuum Technologies Aventics Valves and Valve Systems
Burner Controls Flame Amplifiers For Microprecessor Control Flame Amplifiers For Electromechanical Control ULTRAVIOLET MODUTROL MOTOR SENSORS HONEYWELL MICRO SWITCH SNAP-ACTION SERIES MICRO SWITCH HAZARDOUS AREA SWITCHES KEY AND ROTARY SWITCHES MICRO SWITCH LIMIT SWITCHES Pressuretrol MICROPROCESSOR DISPLAY MODULE MICROPROCESSOR RELAY MODULE ELECTROMECHANICAL RELAY MODULE RELAYS HONEYWELL
Bộ điều khiển nhiệt độ SDC Azbil Burner Controller Azbil Recorder Flame Detector Pressure Transmitters
DECONTACTOR™=SWITCH+SOCKET-OUTLET RETTBOX® (Rescue) MULTICONTACT CONNECTORS INDUSTRIAL PLUGS & SOCKET-OUTLETS SINGLE POLE POWER CONNECTORS CUSTOM SOLUTIONS MULTICONTACT EX EX INDUSTRIAL PLUGS SINGLE POLE EX EX CUSTOM SOLUTIONS
Accessories Actuators - Bộ truyền động Data acquisition and recording Emissions and Combustion Analysis Industrial Automation Sensors and Transmitters Refrigeration
DANH MỤC SẢN PHẨM
  • NAGANOKEIKI NAGANOKEIKI
  • YAMARI - Temperature sensor YAMARI - Temperature sensor
  • M-SYSTEM M-SYSTEM
  • Signal Conditioners
    Two-wire Signal Conditioners
    Power Transducers
    Indicators
    Tower Light
    Limit Alarms
    Gateway-Remote-I/O
    Paperless Recording System
    PC Recorder
    Web Data Loggers
    PID Control Components
    Temperature Controllers
    Electric Actuators
    Lightning Surge Protectors
  • ASCO NUMATIC ASCO NUMATIC
  • BARKSDALE BARKSDALE
  • HONEYWELL HONEYWELL
  • AZBIL - YAMATAKE AZBIL - YAMATAKE
  • MARECHAL MARECHAL
  • ORANGE RESEARCH ORANGE RESEARCH
  • ASCON TECHNOLOGIC ASCON TECHNOLOGIC
  • MAXON - BURNER MAXON - BURNER
  • ECLIPSE - BURNER ECLIPSE - BURNER
  • KROMSCHRODER KROMSCHRODER
  • HUBA CONTROL HUBA CONTROL
  • OMRON OMRON
  • FANTINELLI FANTINELLI
  • HANYOUNG NUX HANYOUNG NUX
  • SCHNEIDER SCHNEIDER
  • TECHNOR TECHNOR
  • STARRETT STARRETT
  • OXFORD-USA OXFORD-USA
  • GENERAL GENERAL
  • DURAG DURAG
  • TESCOM TESCOM
  • MATSUSHIMA MATSUSHIMA
  • DELTA MOBREY DELTA MOBREY
  • GASTRON GASTRON
  • DITEL DITEL
  • TOPWORX TOPWORX
  • ASHCROFT ASHCROFT
  • Taik Electric Taik Electric
  • OPTONE OPTONE
  • GF GF
  • Sirai Sirai
  • ĐỐI TÁC
    • Signal Conditioners
      Signal Conditioners
    • Temperature sensor
      Temperature sensor
    • Process Control - FSG
      Process Control - FSG
    • FLUID CONTROL
      FLUID CONTROL
    • Advance Automation
      Advance Automation
    • Industrial automation Refrigeration
      Industrial automation Refrigeration
    • HUBA CONTROL – For Fine Pressure And Flow Measurement
      HUBA CONTROL – For Fine Pressure And Flow Measurement
    • ELECTRICAL PLUGS & SOCKET-OUTLETS
      ELECTRICAL PLUGS & SOCKET-OUTLETS
    • BURNER
      BURNER
    • BURNER
      BURNER
    M-SYSTEM >> Limit Alarms

    M2EAXV DC ALARM (PC programmable, dual or quad alarm trip

    Cập nhật: 2/17/2020 - Số lượt đọc: 3247
    Thông tin sản phẩm
    Giá: Call  
    Hãng sản xuất: M-system  
    Bảo hành: Số lượt xem:3247  
    M2EAXV Super-mini Signal Conditioners with  Display Mini-M M2E Series

    DC ALARM
    (PC programmable, dual or quad alarm trip)

    Functions & Features
    • Provides relay outputs at preset DC input levels
    • Quad or dual trip
    • Front LCD display indicating values in scaled engineering unit range is used to program the module
    • Adjustable deadband (hysteresis)
    • ON delay time selectable
    • Hi/Lo trip and energized/de-energized coil independently selectable for each setpoint
    • Settable with front button
    • Enclosed relays
    • Relays can be powered by 200 V AC and 100 V DC
    • High-density mounting on DIN rail
    Typical Applications
    • Annunciator
    • Various alarm applications
     

    MODEL: M2EAXV–[1]-[2][3]

    ORDERING INFORMATION
    • Code number: M2EAXV-[1]-[2][3]
    Specify a code from below for each [1] through [3].
      (e.g. M2EAXV-2-M2/Q)
    • Specify the specification for option code /Q
      (e.g. /C01/S01/SET)

    INPUT – Field-selectable
    ◆ DC Input
    • Current input: 0 - 50 mA DC
    • Voltage input: -1000 - +1000 mV DC
    • Voltage input: -10 - +10 V DC

    [1] OUTPUT
    2: 4 points; N.O. or make contact
    3: 4 points; N.C. or break contact
    5: 2 points; SPDT or transfer contact

    [2] POWER INPUT
    AC Power
    M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
     47 – 66 Hz)
    DC Power
    R: 24 V DC
    (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
    P: 110 V DC
    (Operational voltage range 85 – 150 V, ripple 10 %p-p max.)

    [3] OPTIONS
    blank: none
    /Q: With options (specify the specification)

    SPECIFICATIONS OF OPTION: Q (multiple selections)
    COATING (For the detail, refer to M-System's web site.)
    /C01: Silicone coating
    /C02: Polyurethane coating
    /C03: Rubber coating
    TERMINAL SCREW MATERIAL
    /S01: Stainless steel
    EX-FACTORY SETTING
    /SET: Preset according to the Ordering Information Sheet
     (No. ESU-5146)
    Default setting will be used if not otherwise specified.

    RELATED PRODUCTS
    • M2EA configurator software (model: M2EACFG)
    Downloadable at M-System’s web site.
    A dedicated cable is required to connect the module to the PC.  Please refer to the internet software download site or the users manual (EM-5151) for the M2EA configurator for applicable cable types.

    GENERAL SPECIFICATIONS
    Construction: Plug-in
    Connection: M3 screw terminals (torque 0.8 N·m)
    Screw terminal: Chromated steel (standard) or stainless steel
    Housing material: Flame-resistant resin (gray)
    Isolation: input to L1 or L4 alarm output to L2 or L3 alarm output to power
    (for output code 5, L3 alarm output and L4 alarm output is not available)
    Configuration: Program with front buttons or Via PC.
    Programmable features include: Refer to the parameter list.
    Configurator connection: 2.5 dia. miniature jack;
    RS-232-C level

    DISPLAY
    Display functions: Displays and sets measured range, engineering unit
    Display size: Approx. 15.6 × 20.8 mm (0.61” × 0.82”)
    Number of pixels: 68 × 95 (horizontal × vertical)
    Character color: Yellow (reversing display of the current value and the alarm setting value when alarm is tripped)
    Display life: Approx. 60000 hours
    (Expected time for the Display brightness to be reduced to 50 % when the Display is used continuously with brightness setting 2 in 25 ℃)
    Display type: OEL display
    Display digit: Negative 5 digits, positive 6 digits (-99999 to 999999)
    Decimal point position: Selectable

    INPUT SPECIFICATIONS
    ■ DC Current
    Input resistance: Incorporated (23 Ω)
    Input range: 0 - 50 mA DC
    Minimum span: 2 mA
    Offset: Lower range can be any specific value within the input range provided that the minimum span is maintained.
    The measurement available for -5 - +105% of input setting range.
    ■ DC Voltage
    •Narrow Spans (mV)
      Input range: -1000 – +1000 mV DC
      Minimum span: 100 mV
    •Wide Spans (V)
      Input range: -10 – +10 V DC
      Minimum span: 1 V
    Offset: Lower range can be any specific value within the input range provided that the minimum span is maintained.
    Input resistance: 1 MΩ minimum
    The measurement available for -5 - +105% of input setting range.

    OUTPUT SPECIFICATIONS
    ■ Quad Alarm
    Relay rating
    : 100 V AC @ 1 A (cos ø = 1)
    120 V AC @ 1 A (cos ø = 1)
    240 V AC @ 0.5 A (cos ø = 1)
    30 V DC @ 1 A (resistive load)
    Maximum switching voltage: 250 V AC or 125 V DC 
    Maximum switching power: 120 VA or 30 W
    Minimum load: 5 V DC @ 10 mA
    Mechanical life: 5 × 107 cycles
    ■ DUAL ALARM 
    Relay rating
    : 100 V AC @ 4 A (cos ø = 1)
    120 V AC @ 4 A (cos ø = 1)
    240 V AC @ 2 A (cos ø = 1)
    30 V DC @ 4 A (resistive load)
    Maximum switching voltage: 250 V AC or 125 V DC
    Maximum switching power: 480 VA or 150 W
    Minimum load: 5 V DC @ 10 mA
    Mechanical life: 5 × 107 cycles

    INSTALLATION
    Power Consumption
    •AC:
     Max. 5 VA at 100 V
     Max. 6 VA at 200 V
     Max. 7 VA at 264 V
    •DC: ≤ 2.5 W
    Operating temperature: -5 to +55°C (23 to 131°F)
    Operating humidity: 10 to 85 %RH (non-condensing)
    Mounting: Surface or DIN rail
    Weight: 200 g (0.44 lb)

    PERFORMANCE in percentage of FS input
    Accuracy (display accuracy, setting accuracy):
    ± (0.1% of FS + 1 digit)
    See CALCULATION EXAMPLES OF OVERALL ACCURACY.
    Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
    Response time (Filter time constant: 0 sec.): ≤ 0.5 sec. 
    (0 – 100 % at 90 % setpoint)
    Line voltage effect: ±0.1 % over voltage range
    Insulation resistance: ≥ 100 MΩ with 500 V DC
    Dielectric strength: 2000 V AC @ 1 minute (input to L1 or L4 alarm output to L2 or L3 alarm output to power to ground)
    (for output code 5, L3 alarm output and L4 alarm output is not available)

    CALCULATION EXAMPLES OF OVERALL ACCURACY
    [Example] Input Range -10 – +10 V, Input Setting -5 – +5 V
    • Accuracy = Input Range Span (20 V) ÷ Input Span Setting (10 V) × 0.1 % = ±0.2 % + 1 digit

    STANDARDS & APPROVALS
    EU conformity:
    EMC Directive 
      EMI EN 61000-6-4
      EMS EN 61000-6-2
    Low Voltage Directive 
      EN 61010-1
      Measurement Category II (output)
      Installation Category II (power)
      Pollution Degree 2
      Input or output to power: Reinforced insulation (300 V)
      Input to output: Basic insulation (300 V)
      L1 or L4 alarm output to L2 or L3 alarm output: 
      Basic insulation (300 V)
    RoHS Directive
      EN 50581

    EXTERNAL VIEW

    Refer to the operating manual (EM-5146-B) for detailed procedures.

    PARAMETER LIST

    EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)

    SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

    M-System Vietnam
    Tags
    M2EAXV DC ALARM (PC programmable dual or quad alarm trip) M-System - Vietnam
    CÁC TIN KHÁC
    • M2EAXV DC ALARM (PC programmable, dual or quad alarm trip
      Mã số : M2EAXV
      M2EAXV DC ALARM (PC programmable, dual or quad alarm trip) M-System - Vietnam
      Giá:  Call
       | M2EAXV DC ALARM (PC programmable, dual or quad alarm trip
    • AS4V DC ALARM (dual or quad alarm trip; field-configurable)
      Mã số : AS4V
      AS4V DC ALARM (dual or quad alarm trip; field-configurable) M-Sytem Vietnam
      Giá:  Call
       | AS4V DC ALARM (dual or quad alarm trip; field-configurable)
    • ALV DC ALARM
      Mã số : ALV DC ALARM
      ALV DC ALARM M-system Vietnam
      Giá:  Call
       | ALV DC ALARM
    Quảng cáo
    THỐNG KÊ

    may cat giay

    Lượt truy cập: 325357
    may cat giay
    Đang online: 7
    ĐỐI TÁC

    CÔNG TY CỔ PHẦN KỸ THUẬT VÀ THƯƠNG MẠI THIẾT BỊ CÔNG NGHIỆP NTD

    Địa chỉ: Số 28, ngõ 36 Cổ Linh, tổ 7, P. Long Biên, Q. Long Biên, TP. Hà Nội

    Hotline: 0971961212

    sales@ntd-automation.com

    Tags: Yamari Vietnam, M-System Vietnam, Honeywell, Azbil, Yamatake, Ascon Tecnologic, Asco Numatic,
    Thiết kế web bởi haanhco.,ltd
    0971961212 Facebook: 359601070816160Zalo: 0971961212