Việt Nam
English
Marechal
  • Công-ty-CP-Kỹ-Thuật-TM-Thiết-Bị-Công-Nghiệp-NTD-359601070816160/
    TRANG CHỦ
    GIỚI THIỆU
    SẢN PHẨM
    BẢN TIN CÔNG TY
    TUYỂN DỤNG
    LIÊN HỆ
Pressure Gauges Thermocouples Pressure Switch Pressure Sensor Compensating Cable/Duplex Wire Digital Pressure Gauge Resistance Temperature Detectors Temperature Pressure Thermowells Flow & Heat metter
Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Tower Light Limit Alarms Gateway-Remote-I/O Paperless Recording System PC Recorder Web Data Loggers PID Control Components Temperature Controllers Electric Actuators Lightning Surge Protectors
Asco Manually Operated Valves ASCO Medical and Analytical Valves ASCO Numatics Valve Islands ASCO Oil & Gas Valves (ATEX) ASCO Pneumatic Accessories ASCO Proportional Technology Aventics Compressed Air Preparation Aventics Cylinder Accessories Aventics Electrical Connection Technologies Aventics Flow and Check Valves Aventics Pneumatic Connection Technologies Aventics Pressure Regulators Aventics Sensors Aventics Vacuum Technologies Aventics Valves and Valve Systems
Burner Controls Flame Amplifiers For Microprecessor Control Flame Amplifiers For Electromechanical Control ULTRAVIOLET MODUTROL MOTOR SENSORS HONEYWELL MICRO SWITCH SNAP-ACTION SERIES MICRO SWITCH HAZARDOUS AREA SWITCHES KEY AND ROTARY SWITCHES MICRO SWITCH LIMIT SWITCHES Pressuretrol MICROPROCESSOR DISPLAY MODULE MICROPROCESSOR RELAY MODULE ELECTROMECHANICAL RELAY MODULE RELAYS HONEYWELL
Bộ điều khiển nhiệt độ SDC Azbil Burner Controller Azbil Recorder Flame Detector Pressure Transmitters
DECONTACTOR™=SWITCH+SOCKET-OUTLET RETTBOX® (Rescue) MULTICONTACT CONNECTORS INDUSTRIAL PLUGS & SOCKET-OUTLETS SINGLE POLE POWER CONNECTORS CUSTOM SOLUTIONS MULTICONTACT EX EX INDUSTRIAL PLUGS SINGLE POLE EX EX CUSTOM SOLUTIONS
Accessories Actuators - Bộ truyền động Data acquisition and recording Emissions and Combustion Analysis Industrial Automation Sensors and Transmitters Refrigeration
DANH MỤC SẢN PHẨM
  • NAGANOKEIKI NAGANOKEIKI
  • YAMARI - Temperature sensor YAMARI - Temperature sensor
  • M-SYSTEM M-SYSTEM
  • Signal Conditioners
    Two-wire Signal Conditioners
    Power Transducers
    Indicators
    Tower Light
    Limit Alarms
    Gateway-Remote-I/O
    Paperless Recording System
    PC Recorder
    Web Data Loggers
    PID Control Components
    Temperature Controllers
    Electric Actuators
    Lightning Surge Protectors
  • ASCO NUMATIC ASCO NUMATIC
  • BARKSDALE BARKSDALE
  • HONEYWELL HONEYWELL
  • AZBIL - YAMATAKE AZBIL - YAMATAKE
  • MARECHAL MARECHAL
  • ORANGE RESEARCH ORANGE RESEARCH
  • ASCON TECHNOLOGIC ASCON TECHNOLOGIC
  • MAXON - BURNER MAXON - BURNER
  • ECLIPSE - BURNER ECLIPSE - BURNER
  • KROMSCHRODER KROMSCHRODER
  • HUBA CONTROL HUBA CONTROL
  • OMRON OMRON
  • FANTINELLI FANTINELLI
  • HANYOUNG NUX HANYOUNG NUX
  • SCHNEIDER SCHNEIDER
  • TECHNOR TECHNOR
  • STARRETT STARRETT
  • OXFORD-USA OXFORD-USA
  • GENERAL GENERAL
  • DURAG DURAG
  • TESCOM TESCOM
  • MATSUSHIMA MATSUSHIMA
  • DELTA MOBREY DELTA MOBREY
  • GASTRON GASTRON
  • DITEL DITEL
  • TOPWORX TOPWORX
  • ASHCROFT ASHCROFT
  • Taik Electric Taik Electric
  • OPTONE OPTONE
  • GF GF
  • Sirai Sirai
  • ĐỐI TÁC
    • Signal Conditioners
      Signal Conditioners
    • Temperature sensor
      Temperature sensor
    • Process Control - FSG
      Process Control - FSG
    • FLUID CONTROL
      FLUID CONTROL
    • Advance Automation
      Advance Automation
    • Industrial automation Refrigeration
      Industrial automation Refrigeration
    • HUBA CONTROL – For Fine Pressure And Flow Measurement
      HUBA CONTROL – For Fine Pressure And Flow Measurement
    • ELECTRICAL PLUGS & SOCKET-OUTLETS
      ELECTRICAL PLUGS & SOCKET-OUTLETS
    • BURNER
      BURNER
    • BURNER
      BURNER
    M-SYSTEM >> Limit Alarms

    AS4V DC ALARM (dual or quad alarm trip; field-configurable)

    Cập nhật: 2/17/2020 - Số lượt đọc: 2253
    Thông tin sản phẩm
    Giá: Call  
    Hãng sản xuất: M-system  
    Bảo hành: Số lượt xem:2253  
    AS4V  Plug-in Signal Conditioners M-UNIT

    DC ALARM
    (dual or quad alarm trip; field-configurable)

    Functions & Features
    • Provides relay outputs at preset DC input levels
    • Quad or dual trip
    • Setting and display in engineering unit values
    • Setpoint adjustments with the front keypad
    • Software lock
    • Adjustable hysteresis (deadband)
    • On-delay timer
    • Hi/Lo trip and energized/de-energized coil independently selectable for each setpoint
    • Enclosed relays
    • Relays can be powered by 200 V AC and 100 V DC
    • High-density mounting on DIN rail
    Typical Applications
    • Annunciator
    • Various alarm applications
     

    MODEL: AS4V–[1][2]–[3][4]

    ORDERING INFORMATION
    • Code number: AS4V-[1][2]-[3][4]
    Specify a code from below for each of [1] through [4].
      (e.g. AS4V-S22-R/UL/Q)
    • Specify the specification for option code /Q
      (e.g. /C01/SET)

    [1] INPUT
    Current
    Z1: Range 0 – 50 mA DC (Input resistance 100 Ω)
    Voltage
    S1: Range -1 – +1 V DC (Input resistance 1 MΩ min.)
    S2: Range -10 – +10 V DC (Input resistance 1 MΩ min.)

    [2] OUTPUT
    2: 4 points; N.O. or make contact
    3: 4 points; N.C. or break contact
    5: 2 points; SPDT or transfer contact
    2A: 4 points; N.O. or make contact (small load current)
    (CE not available. Option /UL Not selectable.)
    3A: 4 points; N.C. or break contact (small load current)
    (CE not available. Option /UL Not selectable.)
    5A: 2 points; SPDT or transfer contact (small load current)
    (CE not available. Option /UL Not selectable.)

    [3] POWER INPUT
    AC Power
    M2: 100 – 240 V AC, 50 – 60 Hz
     (Operational voltage range 85 – 264 V, 47 – 66 Hz)
    DC Power
    R: 24 V DC
    (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
    P: 110 V DC
    (Operational voltage range 85 – 150 V, ripple 10 %p-p max.)

    [4] OPTIONS (multiple selections)
    Standards & Approvals
    blank: CE marking
    /UL: UL approval, CE marking
    Other Options
    blank: none
    /Q: Option other than the above (specify the specification)

    SPECIFICATIONS OF OPTION: Q (multiple selections)
    COATING (For the detail, refer to M-System's web site.)
    /C01: Silicone coating
    /C02: Polyurethane coating
    /C03: Rubber coating (UL not available)
    TERMINAL SCREW MATERIAL
    /S01: Stainless steel (UL not available)
    EX-FACTORY SETTING
    /SET: Preset according to the Ordering Information Sheet
     (No. ESU-1609)

    GENERAL SPECIFICATIONS
    Construction: Plug-in
    Connection: M3.5 screw terminals
    Screw terminal: Chromated steel (standard) or stainless steel
    Housing material: Flame-resistant resin (black)
    Isolation: Input to output to power
    Sampling cycle: 100 msec.
    User-configurable items: Front key pad
    • Alarm setpoint
    • Display range scaling
    • Power ON-delay time
    • Alarm ON-delay time
    • Moving average
    • Hi/Lo trip operation
    • Coil at alarm
    • Hysteresis (deadband)
    • 0 %, 100 % input setting
    • Latching control
    • Others
    (Refer to the instruction manual)
    ■ DISPLAY
    LED
    : 8 mm (.31”) 7 segment, red
    Number of display digits: 4 digits for DATA display; 2 digits for ITEM display
    Range: -1999 to 9999
    (decimal point position selectable)
    PV indication: Input signal in engineering unit
    Overrange indication: LEDs blinking
    Power saving mode: Displays turn off if the keys are untouched for a preset time period 
    LEDs: Red LEDs turn on when coils are energized.
    (L1 and L2 for 2-point alarm.  L1, L2, L3 and L4 for 4-point alarm.)

    INPUT SPECIFICATIONS
    ■ DC Current: 0 – 50 mA DC; shunt resistor attached to input terminals (0.5 W)
    Operational range: 0 – 70 mA DC (with 100 Ω / 0.5 W)
    Minimum increment: 0.1 mA
    Default setting: 4 – 20 mA DC
    ■ DC Voltage: -1 – +1 V DC for S1;
    -10 – +10 V DC for S2
    Operational range: -1.15 – +1.15 V DC for S1;
    -11.5 – +11.5 V DC for S2
    Minimum increment: 10 mV for S1; 100 mV for S2
    Default setting: -1 – +1 V DC for S1;
    -10 – +10 V DC for S2

    OUTPUT SPECIFICATIONS
    ■ Quad Alarm
    Relay rating: 
    120 V AC @ 1 A (cos ø = 1)
    240 V AC @ 0.5 A (cos ø = 1)
    30 V DC @ 1 A (resistive load)
    Maximum switching voltage(Note): 380 V AC or 125 V DC
    Maximum switching power(Note): 120 VA or 30 W
    Minimum load: 5 V DC @ 10 mA
    Mechanical life: 5 × 107 cycles
    ■ Dual Alarm
    Relay rating: 
    120 V AC @ 5 A (cos ø = 1)
    240 V AC @ 2.5 A (cos ø = 1)
    30 V DC @ 5 A (resistive load)
    Maximum switching voltage(Note): 380 V AC or 125 V DC
    Maximum switching power(Note): 600 VA or 150 W
    Minimum load: 5 V DC @ 10 mA
    Mechanical life: 5 × 107 cycles
    ■ Small load current type
    Relay rating: 
    30 V DC @ 1 A (resistive load)
    Maximum switching voltage(Note): 220 V DC
    Maximum switching power(Note): 30 W  (resistive load)
    Minimum load: 1 V DC @ 1 mA
    Mechanical life: 5 × 107 cycles

    (Note): The value indicate capacity of output relay in equipment.
     Use within relay rating for EU and UL.

    INSTALLATION
    Power consumption
    •AC: ≤ 6 VA
    •DC: ≤ 3.5 W
    Operating temperature: -5 to +55°C (23 to 131°F)
    Operating humidity: 30 to 90 %RH (non-condensing)
    Mounting: Surface or DIN rail
    Weight: 500 g (1.1 lb)

    PERFORMANCE in percentage of FS input
    Setpoint accuracy (trip point accuracy): ±(0.1 % of FS + 1 digit)
    Display accuracy: ±(0.1 % of FS + 1 digit)
    Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
    Response time: ≤ 0.5 sec. (0 – 100 % at 90 % setpoint)
    Line voltage effect: ±0.1 % over voltage range
    Insulation resistance: ≥ 100 MΩ with 500 V DC
    Dielectric strength: 2000 V AC @1 minute  (input to output to power to ground)

    STANDARDS & APPROVALS
    EU conformity:
    EMC Directive 
      EMI EN 61000-6-4
      EMS EN 61000-6-2
    Low Voltage Directive 
      EN 61010-1
      Measurement Category II (output)
      Installation Category II (power)
      Pollution Degree 2
      Input to output to power: Basic insulation (300 V)
    RoHS Directive
      EN 50581
    Approval:
    UL/C-UL general safety requirements
      (UL 61010-1, CAN/CSA-C22.2 No.61010-1)

    EXTERNAL VIEW

    Refer to the instruction manual for detailed procedures.

    EXTERNAL DIMENSIONS unit: mm (inch)

    TERMINAL ASSIGNMENTS unit: mm (inch)

    SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

    M-System Vietnam
    Tags
    AS4V DC ALARM (dual or quad alarm trip; field-configurable) M-Sytem Vietnam
    CÁC TIN KHÁC
    • M2EAXV DC ALARM (PC programmable, dual or quad alarm trip
      Mã số : M2EAXV
      M2EAXV DC ALARM (PC programmable, dual or quad alarm trip) M-System - Vietnam
      Giá:  Call
       | M2EAXV DC ALARM (PC programmable, dual or quad alarm trip
    • AS4V DC ALARM (dual or quad alarm trip; field-configurable)
      Mã số : AS4V
      AS4V DC ALARM (dual or quad alarm trip; field-configurable) M-Sytem Vietnam
      Giá:  Call
       | AS4V DC ALARM (dual or quad alarm trip; field-configurable)
    • ALV DC ALARM
      Mã số : ALV DC ALARM
      ALV DC ALARM M-system Vietnam
      Giá:  Call
       | ALV DC ALARM
    Quảng cáo
    THỐNG KÊ

    may cat giay

    Lượt truy cập: 326052
    may cat giay
    Đang online: 20
    ĐỐI TÁC

    CÔNG TY CỔ PHẦN KỸ THUẬT VÀ THƯƠNG MẠI THIẾT BỊ CÔNG NGHIỆP NTD

    Địa chỉ: Số 28, ngõ 36 Cổ Linh, tổ 7, P. Long Biên, Q. Long Biên, TP. Hà Nội

    Hotline: 0971961212

    sales@ntd-automation.com

    Tags: Yamari Vietnam, M-System Vietnam, Honeywell, Azbil, Yamatake, Ascon Tecnologic, Asco Numatic,
    Thiết kế web bởi haanhco.,ltd
    0971961212 Facebook: 359601070816160Zalo: 0971961212