26RS Head-mounted Two-wire Signal Conditioners 26-UNIT
RTD TRANSMITTER (isolated)
Functions & Features • Accepts direct input from an RTD and provides a standard 4 – 20 mA DC signal • Linearization and burnout • Wide operating temperature range suitable for harsh environments Typical Applications • Mounting in a sensor connection head minimizes noise effect and signal degradation
MODEL: 26RS–[1][2]
ORDERING INFORMATION • Code number: 26RS-[1][2] Specify a code from below for each [1] and [2]. (e.g. 26RS-4/K/BL) • Temperature range (e.g. 0 – 100°C)
[1] INPUT RTD (2- or 3-wire) 1: JPt 100 (JIS ’89) (Usable range: -100 to +500°C, -148 to +932°F, min.span: 50°C, 90°F) 3: Pt 100 (JIS ’89) (Usable range: -100 to +650°C, -148 to +1202°F, min.span: 50°C, 90°F) 4: Pt 100 (JIS ’97, IEC) (Usable range: -100 to +850°C, -148 to +1562°F, min.span: 50°C, 90°F) 5: Pt 50Ω (JIS ’81) (Usable range: -100 to +500°C, -148 to +932°F, min.span: 100°C, 180°F) 6: Ni 508.4 Ω (Usable range: -50 to +200°C, -58 to +392°F; min.span: 30°C, 54°F) Note: Consult M-System for 2-wire RTD
[2] OPTIONS (multiple selections) Response Time (0 – 90 %) blank: Standard (≤ 0.5 sec.) /K: Fast Response (Approx. 25 msec.) Burnout blank: Upscale burnout
/BL: Downscale burnout
M-System Vietnam Office:
No 9, 651/82/3 Minh Khai street- Hai Ba Trung Dist. Hanoi Vietnam
Mã số : 27HU 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
DC mV, V & mA, T/C, RTD and resistance input
8-35 Vdc powered (max. 28 V approved)
ATEX Zone 0 approval
FM Class I, Div. 1 & Zone 0 approval
27HU 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : B6U 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
DC mV, V & mA, T/C, RTD, Pot and resistance input
12-42 Vdc powered (max. 28 V approved)
ATEX Zone 0 approval
FM Class I, Div. 1 & 2 approval
B6U 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : 26TS1 THERMOCOUPLE TRANSMITTER
Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable
12-32 Vdc powered
Fast response 25 msec. optional
26TS1 THERMOCOUPLE TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : B6U-B 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
DC mV, V & mA, T/C, RTD, Pot and resistance input
12-42 Vdc powered (max. 28 V approved)
NEMA 4X, IP66/IP67 enclosure
ATEX Zone 0 approval
FM Class I, II, III, Div. 1 & Class I, II, Div. 2 approval
B6U-B 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : 27RS RTD TRANSMITTER
Pt100, Pt1000, Pt500 selectable
Function monitor LED optional
9-35 Vdc powered
ATEX Zone 0 approval
FM Class I, Div. 1 & Zone 0 approval
27RS RTD TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : 27TS THERMOCOUPLE TRANSMITTER
K, E, J, T, B, R, S, C, D, N, U, L selectable
9-35 Vdc powered
ATEX Zone 0 approval
FM Class I, Div. 1 & Zone 0 approval
27TS THERMOCOUPLE TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : 27U 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
DC mV, V & mA, T/C, RTD and resistance input
9-35 Vdc powered
ATEX Zone 0 approval
FM Class I, Div. 1 & Zone 0 approval
27U 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : 27R RTD TRANSMITTER
Pt100, Pt1000, Pt500 selectable. Non-isolated.
Function monitor LED optional
9-35 Vdc powered
ATEX Zone 0 approval
FM Class I, Div. 1 & Zone 0 approval
27R RTD TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : B5TS - THERMOCOUPLE TRANSMITTER
Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable
12-28 Vdc powered
Fast response 25 msec. optional
B5TS - THERMOCOUPLE TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : 27HU-B 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
DC mV, V & mA, T/C, RTD and resistance input
8-35 Vdc powered (max. 28 V approved)
ATEX Zone 0 approval
FM Class I, Div. 1 & Zone 0 approval
27HU-B 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Functions & Features
• Universal input: mV, V, T/C, RTD, resistance and
potentiometer
• High accuracy
• HART communication
• Intrinsically safe and explosion-proof approval
• Optional stainless steel enclosure
• Programming via hand-held communicator or via PC
• A wide variety of T/C and RTD types
• User’s temperature table can be used
• Self diagnostics
• Input-output isolated