Functions & Features •Easy-to-install, spring-loaded, clamp-on type current sensor •Over-voltage clamp element for safety in open circuit •1 A output
MODEL: CLSD–[1]-[2]-1
ORDERING INFORMATION • Code number: CLSD-[1]-[2]-1 Specify a code from below for each of [1] and [2]. (e.g. CLSD-A-15-1) Special specifications are possible. Consult factory. (Input: 100 to 2000 A, Output: 1 A or Input: 500 to 2000 A, Output: 5 A)
[1] INTERNAL DIAMETER A: 24 (Select 15 or 20 for Input suffix code.) B: 36 (Select 30 or 40 for Input suffix code.) C: 60 ( Select 80 or 100 for Input suffix code.) D: 100 (Select 200 for Input suffix code.)
[2] INPUT 15: 150 A 20: 200 A 30: 300 A 40: 400 A 80: 800 A 100: 1000 A 200: 2000 A
OUTPUT Current 1: 1 A
CAUTION Before you remove the sensor module or mount it, turn off the input signal for safety. While the line is alive, the module’s cores, attracted to each other, may be hard to separate.
RELATED PRODUCTS AC current, watt, power factor transducers with 1 A input •CT input module (model: R3-CT4) •Multi power input module (model: R3-WT1) •AC power input module (model: R3-WT4) •AC current transducer (model: 14CE) •AC current transducer (model: LTCE) •CT transmitter (model: CT) •CT transmitter (model: KCE) •CT transmitter (model: M2CE) •CT converter (model: M8CT) •CT transmitter (model: M5CT) •Multi power monitor (model: 53U, 54U, 54UC, 54UL)
GENERAL SPECIFICATIONS Construction: Clamp Housing material: Flame-resistant resin (black) Applicable wire: Min. 0.75 mm2 Output clamp voltage: ±1.4 Vp-p
INPUT SPECIFICATIONS Max. working voltage: 480 V AC (primary side) Overload capacity: 120 % continuous, 4000 % for 1 minute Operational range CLSD-A-15: ≤ 150 A CLSD-A-20: ≤ 200 A CLSD-B-30: ≤ 300 A CLSD-B-40: ≤ 400 A CLSD-C-80: ≤ 800 A CLSD-C-100: ≤ 1000 A CLSD-D-200: ≤ 2000 A
INSTALLATION Operating temperature: -20 to +60°C (-4 to +140°F) Operating humidity: 85 % RH max. (non-condensing) Mounting: Fix with a binding strap. Weight CLSD-A: 230 g (0.51 lb) CLSD-B: 350 g (0.77 lb) CLSD-C: 500 g (1.1 lb) CLSD-D: 950 g (2.1 lb)
PERFORMANCE Rated primary current / rated secondarycurrent CLSD-A-15: 150 A / 1 A CLSD-A-20: 200 A / 1 A CLSD-B-30: 300 A / 1 A CLSD-B-40: 400 A / 1 A CLSD-C-80: 800 A / 1 A CLSD-C-100: 1000 A / 1 A CLSD-D-200: 2000 A / 1 A Rated VA: 0.5 VA Frequency: 50 / 60 Hz Ratio error: ±1.0 %, 1.0 In / ±1.5 %, 0.2 In Phase displacement error: ±80', 1.0 In / ±120', 0.2 In Insulation resistance: ≥ 100 MΩ with 500 V DC (sensor core to output) Dielectric strength: 2000 V AC @ 1 minute (sensor core to output)
Mã số : CLSE CLAMP-ON CURRENT SENSOR
Easy-to-install, spring-loaded, clamp-on type current sensor
Over-voltage clamp element for safety in open circuit
Wide frequency band
Screw terminal connection
CLSE CLAMP-ON CURRENT SENSOR
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : CLSC - CLAMP-ON CURRENT SENSOR
Easy-to-install, clamp-on type current sensor
Over-voltage clamp element for safety in open circuit
1A Output
Wide frequency band
Screw terminal connection
CLSC - CLAMP-ON CURRENT SENSOR
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : CTS2 - HIGH AC CURRENT TRANSMITTER
Detecting high current at the flexible current probe and
providing a porportional low-ripple standard signal
appropriate for computer use
Wide frequency band can be accepted
Clipped around a conductor without disconnecting the conductor
Rogowski coil type
Isolation up to 2000 V AC
High-density mounting
CTS2 - HIGH AC CURRENT TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : L53U MULTI POWER TRANSDUCER
Single type module is usable for all of single-phase/2-wire and 3-wire, three-phase/3-wire and 4-wire systems.
All measured variables can be transmitted to the host PC via RS-485/Modbus RTU.
Energy count pulse or limit alarm output selectable
Up to 4 optional analog outputs
Remote and local programming using the PC Configurator Software
Input range up to 480 Vac, 1 A or 5 A
DIN rail mounted
L53U MULTI POWER TRANSDUCER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : 54UL MULTI POWER MONITOR
110 x 110 mm panel size
Robust screw terminal connection
Four digital displays
60-segment bargraph
Single-phase/2-wire and 3-wire, three-phase/3-wire and 4-wire systems
All measured variables can be transmitted to the host PC via RS-485/Modbus RTU or CC-Link,LONWORKS
Energy count pulse or limit alarm output selectable
Up to 4 optional analog outputs
Programming lock to prevent unwanted configuration changes
Input range up to 480 Vac, 1 A or 5 A
Modbus:54U CC-Link:54UC LONWORKS:54UL
54UL MULTI POWER MONITOR
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : 54UC MULTI POWER MONITOR
110 x 110 mm panel size
Robust screw terminal connection
Four digital displays
60-segment bargraph
Single-phase/2-wire and 3-wire, three-phase/3-wire and 4-wire systems
All measured variables can be transmitted to the host PC via RS-485/Modbus RTU or CC-Link,LONWORKS
Energy count pulse or limit alarm output selectable
Up to 4 optional analog outputs
Programming lock to prevent unwanted configuration changes
Input range up to 480 Vac, 1 A or 5 A
Modbus:54U CC-Link:54UC LONWORKS:54UL
54UC MULTI POWER MONITOR
M-System Việt Nam
Email: Sales@m-system.com.vn
• Converts alternating current from a current transformer
into a standard process signal
• Minimum ripple
• Isolation up to 2000 V AC
• High-density mounting
• Conforms to IEC 60688