53U Power Transducer Series MULTI POWER MONITOR(4 digital displays)Functions & Features• Measures simultaneously several variables of a heavy-current power system: current, voltage, active, reactive and apparent power, active and reactive energy, power factor, frequency, etc.• All measured values, counter values, display mode, setting data are stored in the non-volatile memory at the power off• Conversion factors, system configuration, interval times are programmable using the front buttons• Open collector output for alarm or energy countTypical Applications• Multi-functional power monitor incorporated in an electric device: saves space, wiring works, and costMODEL: 53U-1[1][2][3]-[4][5]ORDERING INFORMATION• Code number: 53U-1[1][2][3]-[4][5]Specify a code from below for each [1] through [5]. (e.g. 53U-1211-M2/H/UL/Q)• Specify the specification for option code /Q (e.g. /C01/SET)CONFIGURATION1: Single-phase / 2-wire and 3-wire, 3-phase / 3-wire and 4-wire[1] INPUT1: 480 V / 1 A AC2: 480 V / 5 A AC[2] CONTACT INPUT0: None( ‘External Interface’ codes 1, 4 and 5 Not selectable.)1: 24 V DC(‘External Interface’ codes 2, 3, 6, 7, 8 and 9 Not selectable.)2: 110 V DC(‘External Interface’ codes 2, 3, 6, 7, 8 and 9 Not selectable.)[3] EXTERNAL INTERFACE1: Modbus, Do × 1, Di × 12: 4 – 20 mA DC × 43: 1 – 5 V DC × 44: 4 – 20 mA DC × 2, Do × 1, Di × 15: 1 – 5 V DC × 2, Do × 1, Di × 16: 4 – 20 mA DC × 2, Do × 27: 1 – 5 V DC × 2, Do × 28: Modbus, Do × 39: Do × 4[4] AUXILIARY POWER SUPPLYAD4: universal (Option /UL not selectable.)100 – 240 V AC (Operational range 85 – 264 V, 47 – 66 Hz) /110 – 240 V DC (Operational range 99 – 264 V, ripple 10 %p-p max)M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,47 – 66 Hz)[5] OPTIONS (multiple selections)Performanceblank: Standard/H: High accuracy (voltage/current: ±0.2 %, energy: ±0.5 %)Standards & Approvalsblank: CE marking/UL: UL approval, CE markingOther Optionsblank: none/Q: Option other than the above (specify the specification)SPECIFICATIONS OF OPTION: Q (multiple selections)COATING (For the detail, refer to M-System's web site.)Moving parts and indicators are not coated./C01: Silicone coating (UL not available)/C02: Polyurethane coating (UL not available)/C03: Rubber coating (UL not available)EX-FACTORY SETTING/SET: Preset according to the Ordering Information Sheet (No. ESU-6485)
Mã số : CLSE CLAMP-ON CURRENT SENSOR
Easy-to-install, spring-loaded, clamp-on type current sensor
Over-voltage clamp element for safety in open circuit
Wide frequency band
Screw terminal connection
CLSE CLAMP-ON CURRENT SENSOR
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : CLSC - CLAMP-ON CURRENT SENSOR
Easy-to-install, clamp-on type current sensor
Over-voltage clamp element for safety in open circuit
1A Output
Wide frequency band
Screw terminal connection
CLSC - CLAMP-ON CURRENT SENSOR
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : CTS2 - HIGH AC CURRENT TRANSMITTER
Detecting high current at the flexible current probe and
providing a porportional low-ripple standard signal
appropriate for computer use
Wide frequency band can be accepted
Clipped around a conductor without disconnecting the conductor
Rogowski coil type
Isolation up to 2000 V AC
High-density mounting
CTS2 - HIGH AC CURRENT TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : L53U MULTI POWER TRANSDUCER
Single type module is usable for all of single-phase/2-wire and 3-wire, three-phase/3-wire and 4-wire systems.
All measured variables can be transmitted to the host PC via RS-485/Modbus RTU.
Energy count pulse or limit alarm output selectable
Up to 4 optional analog outputs
Remote and local programming using the PC Configurator Software
Input range up to 480 Vac, 1 A or 5 A
DIN rail mounted
L53U MULTI POWER TRANSDUCER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : 54UL MULTI POWER MONITOR
110 x 110 mm panel size
Robust screw terminal connection
Four digital displays
60-segment bargraph
Single-phase/2-wire and 3-wire, three-phase/3-wire and 4-wire systems
All measured variables can be transmitted to the host PC via RS-485/Modbus RTU or CC-Link,LONWORKS
Energy count pulse or limit alarm output selectable
Up to 4 optional analog outputs
Programming lock to prevent unwanted configuration changes
Input range up to 480 Vac, 1 A or 5 A
Modbus:54U CC-Link:54UC LONWORKS:54UL
54UL MULTI POWER MONITOR
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : 54UC MULTI POWER MONITOR
110 x 110 mm panel size
Robust screw terminal connection
Four digital displays
60-segment bargraph
Single-phase/2-wire and 3-wire, three-phase/3-wire and 4-wire systems
All measured variables can be transmitted to the host PC via RS-485/Modbus RTU or CC-Link,LONWORKS
Energy count pulse or limit alarm output selectable
Up to 4 optional analog outputs
Programming lock to prevent unwanted configuration changes
Input range up to 480 Vac, 1 A or 5 A
Modbus:54U CC-Link:54UC LONWORKS:54UL
54UC MULTI POWER MONITOR
M-System Việt Nam
Email: Sales@m-system.com.vn
• Converts alternating current from a current transformer
into a standard process signal
• Minimum ripple
• Isolation up to 2000 V AC
• High-density mounting
• Conforms to IEC 60688