M2PA VOLTAGE TRANSMITTER (Average sensing, RMS calibrated)
Functions & Features • Converts an alternating voltage input from a potential (voltage) transformer into a standard process signal • Minimum ripple Typical Applications • Centralized monitoring and control of power line and power supply voltage measured at switch boards • Monitoring abnormal voltage drops for detecting overload
MODEL: M2PA–[1][2]-[3][4]
ORDERING INFORMATION • Code number: M2PA-[1][2]-[3][4] Specify a code from below for each [1] through [4]. (e.g. M2PA-1A-M2/CE/Q) • Special output range (For codes Z & 0) • Specify the specification for option code /Q (e.g. /C01/S01)
[1] INPUT (sine wave) Voltage 1: 0 – 110 V AC 5: 0 – 150 V AC
[2] OUTPUT Current A: 4 – 20 mA DC (Load resistance 750 Ω max.) B: 2 – 10 mA DC (Load resistance 1500 Ω max.) C: 1 – 5 mA DC (Load resistance 3000 Ω max.) D: 0 – 20 mA DC (Load resistance 750 Ω max.) E: 0 – 16 mA DC (Load resistance 900 Ω max.) F: 0 – 10 mA DC (Load resistance 1500 Ω max.) G: 0 – 1 mA DC (Load resistance 15 kΩ max.) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) 3: 0 – 1 V DC (Load resistance 1000 Ω min.) 4: 0 – 10 V DC (Load resistance 10 kΩ min.) 5: 0 – 5 V DC (Load resistance 5000 Ω min.) 6: 1 – 5 V DC (Load resistance 5000 Ω min.) 0: Specify voltage (See OUTPUT SPECIFICATIONS)
[3] POWER INPUT AC Power M: 85 – 264 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) (Select ‘/N’ for ‘Standards & Approvals’ code.) M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) (90 – 264 V for UL) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) R2: 11 – 27 V DC (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) (Select ‘/N’ for ‘Standards & Approvals’ code.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) (110 V ±10 % for UL)
[4] OPTIONS (multiple selections) Standards & Approvals (must be specified) /N: Without CE or UL /CE: CE marking /UL: UL approval, CE marking Other Options blank: none /Q: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating (UL not available) TERMINAL SCREW MATERIAL /S01: Stainless steel (UL not available)
GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3 screw terminals (torque 0.8 N·m) Screw terminal: Chromated steel (standard) or stainless steel Housing material: Flame-resistant resin (black) Isolation: Input to output to power Input waveform Average sensing: Sine wave Overrange output: 0 to 120 % at 1 – 5 V Zero adjustment: -5 to +5 % (front) Span adjustment: 95 to 105 % (front)
INPUT SPECIFICATIONS Frequency: 50 or 60 Hz Input burden: 0.5 VA max. Overload capacity: 200 % of rating for 1 minute, 120 % continuous Operational range: 0 – 120 % of rating
OUTPUT SPECIFICATIONS ■ DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. ■ DC Voltage: 0 – 12 V DC Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 1 mA max.; at ≥ 0.5 V
INSTALLATION Power Consumption •AC: Approx. 3 VA at 100 V Approx. 4 VA at 200 V Approx. 5 VA at 264 V •DC: Approx. 3 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 150 g (0.33 lb)
PERFORMANCE in percentage of span Accuracy: ±0.4 % Temp. coefficient: ±0.02 %/°C (±0.01 %/°F) Response time: ≤ 0.5 sec. (0 – 90 %) Ripple: 0.5 %p-p max. (100/120 Hz) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground)
STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Installation Category II Pollution Degree 2 Input or output to power: Reinforced insulation (300 V) Input to output: Basic insulation (300 V) RoHS Directive EN 50581 Approval: UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D (ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213) UL/C-UL general safety requirements (UL 61010-1, CAN/CSA-C22.2 No.61010-1)
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
Mã số : W2CE CURRENT TRANSMITTER
0-110 V or 0-150 V
Independent current/voltage output ranges can be specified.
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
W2CE CURRENT TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W2CA CURRENT TRANSMITTER
0-110 V or 0-150 V
Independent current/voltage output ranges can be specified.
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
W2CA CURRENT TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M2FV SIGNAL TRANSMITTER
Free I/O range combinations among 4-20 mA, 0-20 mA, 0-10 V, 2-10 V,
0-5 V and 1-5 V
Response time is also selectable with DIP switch between 0.5 sec. and 30 msec.
85-264, 100-240 Vac or 11-27, 24, 110 Vdc powered
Ideal for quick-relief spare parts
M2FV SIGNAL TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W2DNY CURRENT LOOP SUPPLY
4-20 mA input
Supply output 24-28 V @22 mA
Independent current/voltage output ranges can be specified
100-240 Vac or 24 Vdc powered
Low-end cutout
W2DNY CURRENT LOOP SUPPLY
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M2AC AC TRANSMITTER
Specific input range within 0-250 V or 0-1 A
Min. 40 Hz, max. 1 kHz
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
M2AC AC TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M60SWVS SIGNAL TRANSMITTER
Two isolated outputs
Spring clamp terminal connection for easy wiring
6-mm wide ultra-slim design
Input range field-selectable among 6 options
Output range field-selectable among 4 options
M60SWVS SIGNAL TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W5FV SIGNAL TRANSMITTER
Input range field-selectable among 11 options
Output range field-selectable among 7 options
Optional second output of independent range can be specified when ordering
85-264 Vac or 11-27, 24, 110 Vdc powered (CE for 24 Vdc type)
W5FV SIGNAL TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W2AC AC TRANSMITTER
Specific input range within 0-250 V or 0-1 A
Min. 40 Hz, max. 1 kHz
Independent current/voltage output ranges can be specified.
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
W2AC AC TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M3LV SIGNAL TRANSMITTER
Input selectable within 0-20 mA and ±10 V
Output selectable within 0-20 mA and ±10 V
10-32 Vdc powered
DIP switch or PC configuration
M3LV SIGNAL TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M5MV SIGNAL TRANSMITTER
Specific input range within ±100 mV; current input with a resistor
85-264 Vac or 24 Vdc powered (CE for 24 Vdc type)
Fast response 25 msec. optional
M5MV SIGNAL TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M5DY CURRENT LOOP SUPPLY
4-20 mA input
Supply output 24-28 V @22 mA
Signal output 4-20 mA and other voltage or current range
100-240 Vac or 24 Vdc powered (CE for 24 Vdc type)
Economical model
M5DY CURRENT LOOP SUPPLY
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W5DY CURRENT LOOP SUPPLY
4-20 mA input
Supply output 24-28 V @22 mA
Signal output 4-20 mA and other voltage or current range
Independent output ranges selectable
100-240 Vac or 24 Vdc powered (CE for 24 Vdc type
W5DY CURRENT LOOP SUPPLY
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M2DNY CURRENT LOOP SUPPLY
4-20 mA input
Supply output 24-28 V @22 mA
Signal output 4-20 mA and other voltage or current range
100-240 Vac or 24 Vdc powered
Low-end cutout
M2DNY CURRENT LOOP SUPPLY
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W2TG TACHOGENERATOR TRANSMITTER
Specific input range within 0-250 V
Min. 15 Hz, max. 1 kHz
Independent current/voltage output ranges can be specified.
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
W2TG TACHOGENERATOR TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M2TG TACHOGENERATOR TRANSMITTER
Specific input range within 0-250 V
Min. 15 Hz, max. 1 kHz
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
M2TG TACHOGENERATOR TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Powering a 4 – 20 mA DC current loop
• Applicable to smart transmitters
• Isolation between the input and output
• Fast response type available
• High-density mounting
• Power LED
Signal conditioners convert a field signal from various sensors into standard signal suitable for processing in PLC, DCS or PC-based systems. They are also used to boost a signal to increase load drive capability, to isolate a signal to stop ground loops.
More than 75000 combinations of process signal I/O, power input and mounting configuration are selectable. Additionally, M-System offers the broadest line of signal splitters available.
M2 / M2E Series Signal Conditioners are designed to accept a largest range of process signal inputs and provide a standard and non-standard DC output.
M2E Series are Compact Signal Conditioners with OEL display.