M6SCTC M6NCTCM6DCTC CURRENT TRANSMITTER (clamp-on current sensor)
Functions & Features • Maintenance-free tension clamp connection • Converts AC current signal into a low-ripple standard process signal suitable to be handled for computer inputs • 5.9-mm wide ultra-slim design • Low profile allows the M6S module mounted in a 120-mm deep panel • High-density mounting • Power indicator LED
MODEL: M6SCTC–[1][2]–R[3]
ORDERING INFORMATION • Code number: M6SCTC-[1][2]-R[3] Specify a code from below for each [1] through [3]. (e.g. M6SCTC-56004W-R/Q) • Special output range (For codes Z & 0) • Specify the specification for option code /Q (e.g. /C01) Order Clamp-on current sensor separately.
[1] INPUT Sensor CLSE 5R5: 0 – 5 A AC 550: 0 – 50 A AC 5100: 0 – 100 A AC 5200: 0 – 200 A AC 5400: 0 – 400 A AC 5600: 0 – 600 A AC Sensor CLSB (CE not available) 210: 0 – 10 A AC 215: 0 – 15 A AC 220: 0 – 20 A AC 230: 0 – 30 A AC 240: 0 – 40 A AC 250: 0 – 50 A AC 260: 0 – 60 A AC 275: 0 – 75 A AC 2100: 0 – 100 A AC 2125: 0 – 125 A AC 2150: 0 – 150 A AC 2175: 0 – 175 A AC 2200: 0 – 200 A AC 2225: 0 – 225 A AC 2250: 0 – 250 A AC 2300: 0 – 300 A AC 2350: 0 – 350 A AC 2400: 0 – 400 A AC 2500: 0 – 500 A AC 2600: 0 – 600 A AC
[2] OUTPUT Current A: 4 – 20 mA DC (Load resistance 550 Ω max.) D: 0 – 20 mA DC (Load resistance 550 Ω max.) G: 0 – 1 mA DC (Load resistance 11 kΩ max.) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage 3: 0 – 1 V DC (Load resistance 1000 Ω min.) 4: 0 – 10 V DC (Load resistance 10 kΩ min.) 5: 0 – 5 V DC (Load resistance 5000 Ω min.) 6: 1 – 5 V DC (Load resistance 5000 Ω min.) 4W: -10 – +10 V DC (Load resistance 20 kΩ min.) 5W: -5 – +5 V DC (Load resistance 10 kΩ min.) 0: Specify voltage (See OUTPUT SPECIFICATIONS)
POWER INPUT DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[3] OPTIONS blank: none /Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating
RELATED PRODUCTS • Clamp-on current sensor (model: CLSB) • Clamp-on current sensor (model: CLSE) (Select “CLSE-x/CE” to comply with CE for the combination with the sensor.)
GENERAL SPECIFICATIONS Connection Input and output: Tension clamp Power input: Via the Installation Base (model: M6SBS) or Tension clamp Applicable wire size: 0.2 to 2.5 mm2, stripped length 8 mm Housing material: Flame-resistant resin (black) Isolation: Input to output to power Input waveform RMS sensing: Up to 15 % of 3rd harmonic content Zero adjustment: -2 to +2 % (front) (Output code 4W, 5W: Adjustable at 0V. No output below 0 mA for the code D.) Span adjustment: 98 to 102 % (front) Power LED: Green light turns on when the power is supplied.
INPUT SPECIFICATIONS ■ Clamp-on current sensor CLSE (Sensor model No.: AC input) CLSE-R5: 0 – 5 A CLSE-05: 0 – 50 A CLSE-10: 0 – 100 A CLSE-20: 0 – 200 A CLSE-40: 0 – 400 A CLSE-60: 0 – 600 A Frequency: 50 / 60 Hz Operational range: 5 – 120 % of rating Overload capacity: CLSE-R5: 10 A continuous CLSE-05: 60 A continuous CLSE-10: 120 A continuous CLSE-20: 240 A continuous CLSE-40: 480 A continuous CLSE-60: 720 A continuous Be sure that the input voltage is of 480 V or less. ■ Clamp-on current sensor CLSB (Sensor model No.: AC input) CLSB-05: 0 – 10 A, 0 – 15 A, 0 – 20 A 0 – 30 A, 0 – 40 A, 0 – 50 A CLSB-10: 0 – 60 A, 0 – 75 A, 0 – 100 A CLSB-20: 0 – 125 A, 0 – 150 A, 0 – 175 A 0 – 200 A, 0 – 225 A, 0 – 250 A CLSB-40: 0 – 300 A, 0 – 350 A, 0 – 400 A CLSB-60: 0 – 500 A, 0 – 600 A Frequency: 50 / 60 Hz Operational range: 5 – 120 % of rating Overload capacity: CLSB-05: 100 A continuous CLSB-10: 200 A continuous CLSB-20: 300 A continuous CLSB-40: 600 A continuous CLSB-60: 720 A continuous Be sure that the input voltage is of 440 V or less.
OUTPUT SPECIFICATIONS ■ DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 11 V max. ■ DC Voltage: 0 – 10 V DC Minimum span: 1 V Offset: Max. 1.5 times span Load resistance: Output drive 1 mA max.; at ≥ 1 V
INSTALLATION Power consumption: Approx. 0.5 W Operating temperature: -20 to +55°C (-4 to +131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Installation Base (model: M6SBS) or DIN rail Weight: 60 g (2.1 oz)
PERFORMANCE in percentage of span Accuracy: ±0.5 % with input 5 – 100 % Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: ≤ 1 sec. (0 – 90 %) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground)
STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 RoHS Directive EN 50581
EXTERNAL VIEW
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM M-System Việt Nam Email: Sales@m-system.com.vn
Mã số : W2CE CURRENT TRANSMITTER
0-110 V or 0-150 V
Independent current/voltage output ranges can be specified.
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
W2CE CURRENT TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W2CA CURRENT TRANSMITTER
0-110 V or 0-150 V
Independent current/voltage output ranges can be specified.
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
W2CA CURRENT TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M2FV SIGNAL TRANSMITTER
Free I/O range combinations among 4-20 mA, 0-20 mA, 0-10 V, 2-10 V,
0-5 V and 1-5 V
Response time is also selectable with DIP switch between 0.5 sec. and 30 msec.
85-264, 100-240 Vac or 11-27, 24, 110 Vdc powered
Ideal for quick-relief spare parts
M2FV SIGNAL TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W2DNY CURRENT LOOP SUPPLY
4-20 mA input
Supply output 24-28 V @22 mA
Independent current/voltage output ranges can be specified
100-240 Vac or 24 Vdc powered
Low-end cutout
W2DNY CURRENT LOOP SUPPLY
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M2AC AC TRANSMITTER
Specific input range within 0-250 V or 0-1 A
Min. 40 Hz, max. 1 kHz
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
M2AC AC TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M60SWVS SIGNAL TRANSMITTER
Two isolated outputs
Spring clamp terminal connection for easy wiring
6-mm wide ultra-slim design
Input range field-selectable among 6 options
Output range field-selectable among 4 options
M60SWVS SIGNAL TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W5FV SIGNAL TRANSMITTER
Input range field-selectable among 11 options
Output range field-selectable among 7 options
Optional second output of independent range can be specified when ordering
85-264 Vac or 11-27, 24, 110 Vdc powered (CE for 24 Vdc type)
W5FV SIGNAL TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W2AC AC TRANSMITTER
Specific input range within 0-250 V or 0-1 A
Min. 40 Hz, max. 1 kHz
Independent current/voltage output ranges can be specified.
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
W2AC AC TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M3LV SIGNAL TRANSMITTER
Input selectable within 0-20 mA and ±10 V
Output selectable within 0-20 mA and ±10 V
10-32 Vdc powered
DIP switch or PC configuration
M3LV SIGNAL TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M5MV SIGNAL TRANSMITTER
Specific input range within ±100 mV; current input with a resistor
85-264 Vac or 24 Vdc powered (CE for 24 Vdc type)
Fast response 25 msec. optional
M5MV SIGNAL TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M5DY CURRENT LOOP SUPPLY
4-20 mA input
Supply output 24-28 V @22 mA
Signal output 4-20 mA and other voltage or current range
100-240 Vac or 24 Vdc powered (CE for 24 Vdc type)
Economical model
M5DY CURRENT LOOP SUPPLY
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W5DY CURRENT LOOP SUPPLY
4-20 mA input
Supply output 24-28 V @22 mA
Signal output 4-20 mA and other voltage or current range
Independent output ranges selectable
100-240 Vac or 24 Vdc powered (CE for 24 Vdc type
W5DY CURRENT LOOP SUPPLY
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M2DNY CURRENT LOOP SUPPLY
4-20 mA input
Supply output 24-28 V @22 mA
Signal output 4-20 mA and other voltage or current range
100-240 Vac or 24 Vdc powered
Low-end cutout
M2DNY CURRENT LOOP SUPPLY
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W2TG TACHOGENERATOR TRANSMITTER
Specific input range within 0-250 V
Min. 15 Hz, max. 1 kHz
Independent current/voltage output ranges can be specified.
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
W2TG TACHOGENERATOR TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M2TG TACHOGENERATOR TRANSMITTER
Specific input range within 0-250 V
Min. 15 Hz, max. 1 kHz
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
M2TG TACHOGENERATOR TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Powering a 4 – 20 mA DC current loop
• Applicable to smart transmitters
• Isolation between the input and output
• Fast response type available
• High-density mounting
• Power LED
Signal conditioners convert a field signal from various sensors into standard signal suitable for processing in PLC, DCS or PC-based systems. They are also used to boost a signal to increase load drive capability, to isolate a signal to stop ground loops.
More than 75000 combinations of process signal I/O, power input and mounting configuration are selectable. Additionally, M-System offers the broadest line of signal splitters available.
M2 / M2E Series Signal Conditioners are designed to accept a largest range of process signal inputs and provide a standard and non-standard DC output.
M2E Series are Compact Signal Conditioners with OEL display.