Functions & Features • Converts a DC input into two isolated outputs • Two independent output ranges • DIP switch configurable input & output range • Four-way isolation (input to output 1 to output 2 to power) • High-density mounting Typical Applications • Isolation between control room and field instrumentation
MODEL: W5FV-[1]-[2][3]
ORDERING INFORMATION • Code number: W5FV-[1]-[2][3] Specify a code from below for each [1] through [3]. (e.g. W5FV-6-P/Q) Orders will be shipped at default factory settings for Input (1 – 5V) and Output 1 (4 – 20mA ). • Special 2nd output range (For codes Z & 0) • Specify the specification for option code /Q (e.g. /C01/S01)
INPUT – Field-selectable Current 4 – 20 mA DC (Input resistance 250 Ω) 0 – 20 mA DC (Input resistance 250 Ω) 0 – 10 mA DC (Input resistance 250 Ω) Voltage 0 – 60 mV DC (Input resistance 1 MΩ min.) 0 – 100 mV DC (Input resistance 1 MΩ min.) 0 – 1 V DC (Input resistance 1 MΩ min.) 0 – 10 V DC (Input resistance 1 MΩ min.) 0 – 5 V DC (Input resistance 1 MΩ min.) 1 – 5 V DC (Input resistance 1 MΩ min.) -10 – +10 V DC (Input resistance 1 MΩ min.) -5 – +5 V DC (Input resistance 1 MΩ min.)
OUTPUT 1 – Field-selectable Current 4 – 20 mA DC (Load resistance 550 Ω max.) 0 – 20 mA DC (Load resistance 550 Ω max.) Voltage 0 – 10 V DC (Load resistance 1000 Ω min.) 0 – 5 V DC (Load resistance 500 Ω min.) 1 – 5 V DC (Load resistance 500 Ω min.) -10 – +10 V DC (Load resistance 8000 Ω min.) -5 – +5 V DC (Load resistance 4000 Ω min.)
[1] OUTPUT 2 Y: None Current A: 4 – 20 mA DC (Load resistance 550 Ω max.) B: 2 – 10 mA DC (Load resistance 1100 Ω max.) C: 1 – 5 mA DC (Load resistance 2200 Ω max.) D: 0 – 20 mA DC (Load resistance 550 Ω max.) E: 0 – 16 mA DC (Load resistance 685 Ω max.) F: 0 – 10 mA DC (Load resistance 1100 Ω max.) G: 0 – 1 mA DC (Load resistance 11 kΩ max.) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) 3: 0 – 1 V DC (Load resistance 100 Ω min.) 4: 0 – 10 V DC (Load resistance 1000 Ω min.) 5: 0 – 5 V DC (Load resistance 500 Ω min.) 6: 1 – 5 V DC (Load resistance 500 Ω min.) 4W: -10 – +10 V DC (Load resistance 2000 Ω min.) 5W: -5 – +5 V DC (Load resistance 1000 Ω min.) 0: Specify voltage (See OUTPUT SPECIFICATIONS)
[2] POWER INPUT AC Power M: 85 – 264 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) (CE not available) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) R2: 11 – 27 V DC (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) (CE not available) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) (CE not available)
[3] OPTIONS blank: none /Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL /S01: Stainless steel
GENERAL SPECIFICATIONS Construction: Terminal block Connection Input: M3.5 screw terminals (torque 0.8 N·m) Output & power: M3 screw terminals (torque 0.8 N·m) Screw terminal: Nickel-plated steel (standard) or stainless steel Housing material: Flame-resistant resin (black) Isolation: Input to output 1 to output 2 to power Overrange output: Approx. -10 to +120 % at 1 – 5 V Zero adjustment: -2 to +2 % (front) (±1 % with ±5 V and ±10 V input ranges) Span adjustment: 98 to 102 % (front) (99 to 101 % with ±5 V and ±10 V input ranges)
INPUT SPECIFICATIONS ■ DC Current: Input resistor incorporated • DC Voltage Input resistance: 1 MΩ min.
OUTPUT SPECIFICATIONS OUTPUT 2 ■ DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 11 V max. ■ DC Voltage: -10 – +12 V DC Spans: Min. 5 mV, max. 20 V Offset: Max. 1.5 times span Load resistance: Output drive 10 mA max.; 5 mA for negative voltage output; at ≥ 0.5 V
INSTALLATION Power Consumption •AC: Approx. 4 VA at 100 V Approx. 5 VA at 200 V Approx. 6 VA at 264 V •DC: Approx. 3 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 0 to 90 %RH (non-condensing) Mounting: DIN rail Weight: 130 g (0.29 lb)
PERFORMANCE in percentage of span Accuracy: ±0.1 % Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: ≤ 0.5 sec. (0 – 90 %) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output 1 or output 2 to power to ground) 1000 V AC @1 minute (output 1 to output 2)
STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 RoHS Directive EN 50581
EXTERNAL VIEW
INPUT RANGE (DIP SW) Input exceeding the maximum value of each input range may destroy the transmitter. Be sure to confirm the setting range before applying input signals. Input range setting accuracy: Approx. 1 % (≤ 2 % when both input and output ranges are modified.)
OUTPUT RANGE (DIP SW) Only Output 1 is field-configurable. Specify Output 2 range when ordering. Output range setting accuracy: Approx. 1 % (≤ 2 % when both input and output ranges are modified.)
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
Mã số : W2CE CURRENT TRANSMITTER
0-110 V or 0-150 V
Independent current/voltage output ranges can be specified.
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
W2CE CURRENT TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W2CA CURRENT TRANSMITTER
0-110 V or 0-150 V
Independent current/voltage output ranges can be specified.
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
W2CA CURRENT TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M2FV SIGNAL TRANSMITTER
Free I/O range combinations among 4-20 mA, 0-20 mA, 0-10 V, 2-10 V,
0-5 V and 1-5 V
Response time is also selectable with DIP switch between 0.5 sec. and 30 msec.
85-264, 100-240 Vac or 11-27, 24, 110 Vdc powered
Ideal for quick-relief spare parts
M2FV SIGNAL TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W2DNY CURRENT LOOP SUPPLY
4-20 mA input
Supply output 24-28 V @22 mA
Independent current/voltage output ranges can be specified
100-240 Vac or 24 Vdc powered
Low-end cutout
W2DNY CURRENT LOOP SUPPLY
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M2AC AC TRANSMITTER
Specific input range within 0-250 V or 0-1 A
Min. 40 Hz, max. 1 kHz
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
M2AC AC TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M60SWVS SIGNAL TRANSMITTER
Two isolated outputs
Spring clamp terminal connection for easy wiring
6-mm wide ultra-slim design
Input range field-selectable among 6 options
Output range field-selectable among 4 options
M60SWVS SIGNAL TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W5FV SIGNAL TRANSMITTER
Input range field-selectable among 11 options
Output range field-selectable among 7 options
Optional second output of independent range can be specified when ordering
85-264 Vac or 11-27, 24, 110 Vdc powered (CE for 24 Vdc type)
W5FV SIGNAL TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W2AC AC TRANSMITTER
Specific input range within 0-250 V or 0-1 A
Min. 40 Hz, max. 1 kHz
Independent current/voltage output ranges can be specified.
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
W2AC AC TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M3LV SIGNAL TRANSMITTER
Input selectable within 0-20 mA and ±10 V
Output selectable within 0-20 mA and ±10 V
10-32 Vdc powered
DIP switch or PC configuration
M3LV SIGNAL TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M5MV SIGNAL TRANSMITTER
Specific input range within ±100 mV; current input with a resistor
85-264 Vac or 24 Vdc powered (CE for 24 Vdc type)
Fast response 25 msec. optional
M5MV SIGNAL TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M5DY CURRENT LOOP SUPPLY
4-20 mA input
Supply output 24-28 V @22 mA
Signal output 4-20 mA and other voltage or current range
100-240 Vac or 24 Vdc powered (CE for 24 Vdc type)
Economical model
M5DY CURRENT LOOP SUPPLY
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W5DY CURRENT LOOP SUPPLY
4-20 mA input
Supply output 24-28 V @22 mA
Signal output 4-20 mA and other voltage or current range
Independent output ranges selectable
100-240 Vac or 24 Vdc powered (CE for 24 Vdc type
W5DY CURRENT LOOP SUPPLY
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M2DNY CURRENT LOOP SUPPLY
4-20 mA input
Supply output 24-28 V @22 mA
Signal output 4-20 mA and other voltage or current range
100-240 Vac or 24 Vdc powered
Low-end cutout
M2DNY CURRENT LOOP SUPPLY
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : W2TG TACHOGENERATOR TRANSMITTER
Specific input range within 0-250 V
Min. 15 Hz, max. 1 kHz
Independent current/voltage output ranges can be specified.
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
W2TG TACHOGENERATOR TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Mã số : M2TG TACHOGENERATOR TRANSMITTER
Specific input range within 0-250 V
Min. 15 Hz, max. 1 kHz
100-240 Vac or 24 Vdc powered
UL/cUL Class I, Div. 2 approval
M2TG TACHOGENERATOR TRANSMITTER
M-System Việt Nam
Email: Sales@m-system.com.vn
Powering a 4 – 20 mA DC current loop
• Applicable to smart transmitters
• Isolation between the input and output
• Fast response type available
• High-density mounting
• Power LED
Signal conditioners convert a field signal from various sensors into standard signal suitable for processing in PLC, DCS or PC-based systems. They are also used to boost a signal to increase load drive capability, to isolate a signal to stop ground loops.
More than 75000 combinations of process signal I/O, power input and mounting configuration are selectable. Additionally, M-System offers the broadest line of signal splitters available.
M2 / M2E Series Signal Conditioners are designed to accept a largest range of process signal inputs and provide a standard and non-standard DC output.
M2E Series are Compact Signal Conditioners with OEL display.