R1D-GH2
Remote I/O R1X Series
THERMOCOUPLE & DC INPUT MODULE (16 points; DeviceNet)
Functions & Features • 16-point thermocouple or DC inputs • DeviceNet interface
MODEL: R1D-GH2T-[1][2]
ORDERING INFORMATION • Code number: R1D-GH2T-[1][2] Specify a code from below for each [1] and [2]. (e.g. R1D-GH2T-M2/Q) • Specify the specification for option code /Q (e.g. /C01) • Use Ordering Information Sheet (No. ESU-5956). Default setting will be used if not otherwise specified. Factory default setting Input type: DC Voltage ±5 V Burnout protection: No burnout Cold junction compensation: No
FIELD TERMINAL TYPE T:M3 screw terminals
[1] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[2] OPTIONS blank: none /Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating
RELATED PRODUCTS • Resistor module (model: REM3-250) • R1X configurator software (model: R1CON) • EDS file The EDS file and configurator software are downloadable at M-System’s web site. A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types.
GENERAL SPECIFICATIONS Connection Power input, DeviceNet: Euro type connector terminal (applicable wire size: 0.2 to 2.5 mm2 (AWG24 to 12), stripped length 7 mm) Input: M3 screw terminals (torque 0.6 N·m) Configurator: 2.5 dia. miniature jack; RS-232-C level Screw terminal: Nickel-plated steel Housing material: Flame-resistant resin (gray) Isolation: Input to DeviceNet to power Power indicator: Green LED turns on with power supplied.
DeviceNet COMMUNICATION Transmission cable: Approved for DeviceNet Node address setting: Rotary switch or software; 00 – 63 Baud rate setting: DIP switch or software MS (Module Status) indicator: Bi-color (green/red) LED indicates device status. NS (Network Status) indicator: Bi-color (green/red) LED indicates status of the communication link. Device Profile: Generic Device
INPUT SPECIFICATIONS ■ Thermocouple or DC input, 16 points (Common negative for DC input) •Measuring range ±20 V, ±5 V, ±1 V: Atten. SW ON (3) •Measuring range ±0.8 V, ±0.2 V, ±50 mV, ±10m V: Atten. SW OFF (1) Input resistance: 300 kΩ Thermocouple types: PR, K, E, J, T, B, R, S, C, N, U, L, P Sampling rate: 150 millisec./16 points ■ A/D conversion output: 16-bit signed binary (negative range represented by 2’s complements) Engineering unit value is converted into A/D conversion data as shown below. Input type & range: A/D data (decimal) ±20 V: ±20000 ±5 V: ±5000 ±1 V: ±10000 ±0.8 V: ±8000 ±0.2 V: ±20000 ±50 mV: ±5000 ±10 mV: ±10000 Thermocouples: Temperature × 10 In order to change input type and range after shipment, the R1X configurator software (model: R1CON) is required.
INSTALLATION Power consumption •AC:Approx. 6 VA •DC: Approx. 2 W Supply voltage to network: 11 – 25 V DC supplied through the network terminal block Supply current to network: 50 mA max. Operating temperature: -5 to +60°C (23 to 140°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 380 g (0.84 lb)
PERFORMANCE (% of measuring range) Accuracy DC input: ±0.3 % Thermocouple input: See the table on the end of this section. Cold junction compensation error: ±3°C or ±5.4°F max. (at 20°C ±10°C or 68°F ±18°F) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) ±0.05 %/°C (±0.03 %/°F) for 10 mV range and T/C B (RH) Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (input to DeviceNet to power to FG)
EXTERNAL VIEW
CONNECTION DIAGRAM
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)